JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


RIS citation export for TUPB12: Assessment of the Corrosion of Copper Components in the Water Cooling System of ALBA Synchrotron Light Source; Presentation of a Proposal to Mitigate the Corrosion Rate of Copper

TY  - CONF
AU  - Quispe, M.
AU  - Ayas, E.
AU  - Buxadera, J.
AU  - Casas, J.J.
AU  - Colldelram, C.
AU  - Fuentes, Ll.
AU  - Giraldo, J.C.
AU  - Iglesias, J.
AU  - Pont, M.
AU  - Punset, M.
ED  - Jaski, Yifei
ED  - Den Hartog, Patric
ED  - Jaje, Kelly
ED  - Schaa, Volker R.W.
TI  - Assessment of the Corrosion of Copper Components in the Water Cooling System of ALBA Synchrotron Light Source; Presentation of a Proposal to Mitigate the Corrosion Rate of Copper
J2  - Proc. of MEDSI2020, Chicago, IL, USA, 24-29 July 2021
CY  - Chicago, IL, USA
T2  - Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation
T3  - 11
LA  - english
AB  - This paper presents the most recent results on the corrosion of copper components in ALBA water cooling system. The studies have been carried out using a variety of techniques: Scanning Electron Microscopy (SEM), Energy-Dispersive X-Ray Spectroscopy (EDS) and X-Ray Diffraction (XRD). Representative samples of the Accelerator Facility were examined: Storage Ring Absorbers, Front End Masks, Radio Frequency Cavity Pipes, Experimental Line Mask, Radio Frequency Plant Pipes at Service Area and Booster Quadrupole. The studies show the presence of intergranular, pitting and generalized corrosion. The presence of copper oxide is confirmed, as well as other elements such as Aluminum, Carbon, Sulfur, Silver, Calcium, Silicon, Titanium and Iron in some regions of the samples. Likewise, other elements from circulating water such as Potassium and Chlorine have also been detected. The depth of pitting corrosion is less than 119.4 um for the samples studied, after 10 years of operation. To minimize the corrosion problem, an upgrade of the ALBA cooling system is under study. The objective is to reduce the current corrosion rate by a conservative factor of 5. This change is possible by modifying the characteristics of the cooling water, reducing the dissolved oxygen content to values below 10 ppb and increasing the pH above 7.5. Technical aspects of this upgrade are discussed in this paper.
PB  - JACoW Publishing
CP  - Geneva, Switzerland
SP  - 171
EP  - 174
KW  - cavity
KW  - operation
KW  - radio-frequency
KW  - controls
KW  - quadrupole
DA  - 2021/10
PY  - 2021
SN  - 2673-5520
SN  - 978-3-95450-229-5
DO  - doi:10.18429/JACoW-MEDSI2020-TUPB12
UR  - https://jacow.org/medsi2020/papers/tupb12.pdf