JACoW logo

Joint Accelerator Conferences Website

The Joint Accelerator Conferences Website (JACoW) is an international collaboration that publishes the proceedings of accelerator conferences held around the world.


BiBTeX citation export for WEPA16: Development and Applications of the White Beam Position Monitor for Bending Magnet Beamlines

@inproceedings{chang:medsi2020-wepa16,
  author       = {C.Y. Chang and C.F. Chang and C.H. Chang and S.H. Chang and L.C. Chiang and R. Lee and B.Y. Liao and C.Y. Liu},
% author       = {C.Y. Chang and C.F. Chang and C.H. Chang and S.H. Chang and L.C. Chiang and R. Lee and others},
% author       = {C.Y. Chang and others},
  title        = {{Development and Applications of the White Beam Position Monitor for Bending Magnet Beamlines}},
  booktitle    = {Proc. MEDSI'20},
  pages        = {263--265},
  eid          = {WEPA16},
  language     = {english},
  keywords     = {radiation, simulation, controls, synchrotron-radiation, synchrotron},
  venue        = {Chicago, IL, USA},
  series       = {Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation},
  number       = {11},
  publisher    = {JACoW Publishing, Geneva, Switzerland},
  month        = {10},
  year         = {2021},
  issn         = {2673-5520},
  isbn         = {978-3-95450-229-5},
  doi          = {10.18429/JACoW-MEDSI2020-WEPA16},
  url          = {https://jacow.org/medsi2020/papers/wepa16.pdf},
  note         = {https://doi.org/10.18429/JACoW-MEDSI2020-WEPA16},
  abstract     = {{We developed a white beam position detector to be applied in beamlines with bending magnets. By 0.1 mm light-receiving opening, the beam is split and converted to a photocurrent intensity which can be used to detect the size and position of the beam is less than or equal to 50 mm, and to locate the positions of the beamline components. This is a stop-beam measurement method, so it cannot be used to monitor the beam in real time. The motorized stage of the detector has a range of motion up to ± 25 mm with position accuracy not more than 1 micrometer and vacuum capability not more than 5 × 10 -10 Torr, which is compatible with ultra-high vacuum environments. In addition, taking the thermal load 62.89 W of the TPS 02A beamline as an example, the thermal deformation of the analog detector opening lead to a result that the measured value will have a maximum of 2 micrometer from the center of the beam. Finally, and the whole system has been successfully applied in the TPS 02A beamline.all features are verified and the performance meets the requirements, Besides the positioning tasks of Mask and Slits1 was completed and the position change of the light source was detected.}},
}