Author: Alvarez, J.M.    [Álvarez, J.M.]
Paper Title Page
WEPA11 Design of Monochromatic and White Beam Fluorescence Screen Monitors for XAIRA Beamline at the ALBA Synchrotron 249
 
  • J.M. Álvarez, C. Colldelram, N González, J. Juanhuix, J. Nicolás, I. Šics
    ALBA-CELLS Synchrotron, Cerdanyola del Vallès, Spain
 
  XAIRA, the hard X-ray microfocus beamline at ALBA, includes three monochromatic fluorescence screens and one water cooled white beam monitor in its layout, mounting respectively YAG:Ce and polycrystalline CVD diamond as scintillator screens. All monitors share the same design scheme, with a re-entrant viewport for the visualization system that allows reducing the working distance, as required for high magnification imaging. The scintillator screen assembly is held by the same CF63 flange, making the whole system very compact and stable. The re-entrant flange is driven by a stepper motor actuated linear stage that positions or retracts the screen with respect to the beam path. To cope with high power density (18, 6 W/m2) on the white beam monitor 100 µm-thick diamond screen, an InGa-based cooling system has been developed. The general design of the new fluorescence screens, to be used also in other ALBA’s upcoming beamlines, with particular detail on the water-cooled white beam monitor, is described here.  
poster icon Poster WEPA11 [0.913 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2020-WEPA11  
About • paper received ※ 25 July 2021       paper accepted ※ 19 October 2021       issue date ※ 04 November 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)