Author: Pradhan, P.
Paper Title Page
WEPC10 Design of Vacuum Chamber With Cryogenic Cooling of Samples for Bragg-Plane Slope Error Measurements 327
 
  • J.W.J. Anton, P. Pradhan, D. Shu, Yu. Shvyd’ko
    ANL, Lemont, Illinois, USA
 
  Funding: Work supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357.
Wavefront preservation is essential for numerous X-ray science applications. Research is currently underway at the Advanced Photon Source to characterize and minimize Bragg-plane slope errors in diamond crystal optics*. Understanding the effect of cooling the optics to cryogenic temperatures on Bragg-plane slope errors is of interest to this research. Through the use of a finite element model a custom, compact vacuum chamber with liquid nitrogen cooling of samples was designed and manufactured. The design process and initial results are discussed in this paper.
*P. Pradhan et al., J. of Synchrotron Radiation 6, 1553 (2020)
 
poster icon Poster WEPC10 [0.903 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2020-WEPC10  
About • paper received ※ 13 August 2021       paper accepted ※ 19 October 2021       issue date ※ 01 November 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)