Author: Gubbels, E.
Paper Title Page
MOPB13 Automated Mechanical Inspection and Calibration of Insertion Devices in APS Storage Ring 50
 
  • N.R. Weir, E. Gubbels
    ANL, Lemont, Illinois, USA
 
  Funding: Argonne National Laboratory under Contract No. DE-AC02-06CH11357.
A novel technique has been developed to automatically inspect and calibrate the 53 permanent magnet insertion devices in the Advanced Photon Source (APS) storage ring. This technique employs standard frequency domain analysis to create easily identifiable signatures in an actionable format. We will discuss the mechanisms and actions taken behind various observed trends and its application for continuous monitoring and predictive maintenance of these devices. This technique has enabled predictive maintenance and provided new insights into optimizing device performance.
 
poster icon Poster MOPB13 [1.783 MB]  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2020-MOPB13  
About • paper received ※ 26 July 2021       paper accepted ※ 01 October 2021       issue date ※ 30 October 2021  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)